| The Marlin Condition Detector Pro IS (MCD) is certified Intrinsically Safe (IS) for Europe and North America. The rugged unit is certified for use in hazardous environment. The MCD provides a simple but extremely effective means of checking the health of a machine, measuring vibration and temperature to assess its operating state.
By putting MCD into the hand of plant or maintenance personnel, the frequency of checking can be increased, warnings can be received earlier and plant condition experts can be freed to focus only on specific problem areas.
Measure Vibration in terms of Velocity and Acceleration Enveloping Overall Velocity vibration is an excellent measurement parameter for determining rotational and structural problems such as imbalance, misalignment, looseness and stress applied to components. Acceleration Enveloping measures higher frequencies usually associated with bearing problems and gear mesh.
Measure Temperature Temperature is measured by a unique sensing magnet to detect and signal temperatures values outside of the acceptable range. Temperature measurements enhance the "early warning" benifit of the instrument by offering a useful indication of mechanical condition or the load applied to a specific component. As a bearing or lubrication fails, friction causes its temperature to rise.
General Alarm Capabilities The MCD is easilly programmed for six alarm settings. When measurements are taken, they are automatically compared to six user-defined settings. The MCD's alarm indicating LED's react appropriately and indicate Green if OK, Yellow for 1st Level Alarm, and Red for 2nd Level Alarm.
Intrinsically Safe Approval ATEX: II1G EEx ia IIC T4 (Ta= -20°C to +40°C0 Class I, Div I, Groups A,B,C,D T3A (USA, Canada)
Features:
- Small and Rugged
- Overall Vibration in terms of Velocity
- Acceleration Enveloping
- Temperature Magnet
- Includes Vibration Severity Chart
- Programmable Alarms
- Visible LED Indicators
- "Green" OK Indication
- "Amber" 1st Level Alarm Indication
- "Red" 2nd Level Alarm Indication
- Programmable English or Metric
- Intrinsically Safe: ATEX approved
Download Datasheet
Kit Includes:
- MCD
- Magnetic base with temperature sensor
- 4" stinger probe
- Setup key
- Padded carry case
- User manual and quick start card
Specifications:
- Measurements
- Velocity Sensor: Integrated Piezoelectric Accelerometer, Ceramic, Shear Type
- Measurement Range:
- Velocity: 0.3 - 55 mm/sec RMS 0.02 - 3.0 in/sec (Eq. Peak)
- Enveloped Acceleration: 0.3 gE - 20.0 gE
- Temperature: +32°F to 212°F, 0°C to +100°C
- Frequency Range:
- Overall Velocity: 10 Hz - 1 kHz
- Enveloped Acceleration: Band 3, 500 Hz to 10 KHz
- Display
- Viewing Area: 2.165" x 0.700" (54.99mm x 17.78mm)
- Power
- Main Power: Two (2) 1.5 V alkaline "AA" batteries
- Battery Lifetime: Thirty (30) hours
- Backup Battery: One (1) 3 V BR1225 Lithium Ion Battery
- Auto Off: Two (2) minute countdown on last operation
- Physical
- Case: Water & Dust Resistant, IP65
- Drop Test: Six (6) feet on multiple axis
- Dimensions: Length: 7.50" (190.5 mm)
- Width: 1.70" (43.2 mm)
- Height: 1.63" (41.4 mm)
- Weight: 0.95 lb (431 grams) with battery 1.40 lb (635 grams) with temp. magnet
- Environment
- Operating Temperature:
- -4°F to +140°F (-20°C to +60°C) standard locations
- -4°F to +104°F (-20°C to +40°C) hazardous locations
- Storage Temperature: -34°F to 158°F (-37°C to +70°C)
- Humidity: 5-95% noncondensing
|