Fuzzy Logic PID, Auto Tuning, and Soft Start features combine for uncompromising, state-of-the-art control
Extech controllers now offer Fuzzy Logic enhanced PID and a Soft-Start feature that protects heaters from cold-starts. PID plus Fuzzy Logic tackles even the most demanding applications, eliminating over-shoot, unwanted process fluctuations, and drift. The Soft Start feature is ideally suited for processes, such as those employed in the Thermo-Plastics industry, where careful, exact, and slow heating of product is required.
Features:
- Dual 4-digit LED displays for process and setpoint values
- 1/16 DIN (48VFL) and 1/4 DIN (96VFL) model dimensions available
- Easy programming & navigation with user-friendly menus and tactile keypad
- Fuzzy Logic PID offers intuitive control simulating human control logic
- Manual mode allows the user to override automatic control and drive the controller output higher or lower with the touch of a button
- One-touch Auto Tuning for quick setup and stable, precise control
- Two ¡®Latching¡¯ Alarm relays standard with 8 Alarm modes plus advanced Timer modes
- Single stage Ramp and Soak program with Ramp-to-Setpoint Limit that can be combined with the Soft Start feature for critical process demands
- Accepts thermocouple and RTD inputs
- Select desired temperature display units (¡ÆF or ¡ÆC) from setup menu
- Select thermocouple input type (9 selections) or RTD input (2 selections) from the display menu without the need for hardware modification
- Complete with mounting bracket hardware and screw terminals for easy wiring
Specfications
| Thermocouple |
|
|
| Inputs |
Type K |
-58 to 2498¡ÆF (-50 to 1370¡ÆC) |
|
Type J |
-58 to 1832¡ÆF (-50 to 1000¡ÆC) |
|
Type B |
32 to 3272¡ÆF ( 0 to 1800¡ÆC) |
|
Type T |
-454 to 752¡ÆF (-270 to 400¡ÆC) |
|
Type E |
-58 to 1382¡ÆF (-50 to 750¡ÆC) |
|
Type R or S |
32 to 3182¡ÆF ( 0 to 1750¡ÆC) |
|
Type N |
-58 to 2372¡ÆF (-50 to 1300¡ÆC) |
|
Type C |
-58 to 3272¡ÆF (-50 to 1800¡ÆC) |
|
PT100¥Ø RTD (DIN) |
-328 to 1652¡ÆF (-200 to 850¡ÆC) |
|
PT100¥Ø RTD (JIS) |
-328 to 1202¡ÆF (-200 to 650¡ÆC) |
|
Control/Alarm Relay |
5 Amp @ 110V, SPST (resistive load) |
|
DC Current Output |
4-20mA (resistive); Impedance < 600 ohms |
|
Accuracy |
Thermocouple: ¡¾1.8¡ÆF (1¨¬C); RTD: ¡¾0.36¡ÆF (0.2¨¬C) |
|
Sampling Time |
Four (4) samples per second |
|
LED Display |
Two 4-digit displays for Process Value, Setpoint, and programming modes |
|
LED Status |
Alarm and Control output status |
|
Control Modes |
Fuzzy Logic enhanced three-term PID with Auto Tune
-
Proportional Band 0 to 300.0%
-
Integral time 0 to 3600 seconds
-
Derivative time 0 to 900 seconds
-
Hysteresis 0.0 to 200.0 or 0.0 to 2000
-
Cycle time 1 to 100 seconds |
|
Front Panel |
Lexan construction, Drip/Dust proof; IR rating: IEC IP63 |
|
Power Supply |
90 to 264 VAC; 50/60 Hz (< 5VA power consumption) |
|