Home > Intrinsically Safe >

Fluke 28 II Ex Intrinsically Safe True-RMS Digital Multimeter
Fluke 28 II Ex Intrinsically Safe True-RMS Digital Multimeter
 
Alternative Views:


Our Price: $1,699.99

Product Code: ECO-481149-
Qty:

Description
 
Fluke 28 II Ex/ETL Intrinsically Safe True RMS Digital Multimeter 4017176 is capable of being used both inside and outside ATEX zones 1, 2, 21, or 22 to get the job done with one instrument. Extremely durable meter to handle any conditions Mother Nature might throw its way. The Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter measures AC/DC Voltage, AC/DC Current, Resistance, Conductance, Diode Test, Duty Cycle, Capacitance, Frequency, and Temperature.

Now theres one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zone 1 and 2 and IIIC (dust), Zone 21 and 22. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28 II Ex is also waterproof, dust-proof and drop-proof. Youll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance.

INTRINSICALLY SAFE VERSION OF 28II WITH ETL APPROVAL

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 ft or 3 m (with holster)
  • Dustproof per IEC60529 IP6x
  • Waterproof per IEC60529 IPx7
  • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001
    • Measurement Category III, 1000V, Pollution Degree 2
    • Measurement Category IV, 600V, Pollution Degree 2
  • Reversible holster for added protection of the display when not in us


DOWNLOAD DATASHEET



Specifications: Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter

Accuracy Specifications
Accuracy specifications are shown as (% of reading + number of digits)
DC voltageRange0.1 mV to 1000 V
Accuracy0.05% + 1
AC voltageRange0.1 mV to 1000 V
Accuracy0.7% +4
DC currentRange0.1 A to 10 A
Accuracy0.2% + 4
AC currentRange0.1 A to 10 A
Accuracy1.0% + 2
ResistanceRange0.1 to 50 M
Accuracy(0.2% + 1)
ConductanceRange60.00 nS
Accuracy(1.0% + 10)
Diode testRange2.0 V
Accuracy(2.0% + 1)
Duty cycleRange0.0% to 99.9%
AccuracyWithin (0.2% per kHz + 0.1%) for rise times <1 s
CapacitanceRange10 nF to 9999 F
Accuracy(1.0% + 2)
FrequencyRange0.5 Hz to 199.99 kHz
Accuracy(0.005% + 1)
TemperatureRange-200C to +1090C (-328F to +1994F)
Accuracy(1.0% + 10)C [(1.0% + 10)F]
Display counts6000 counts/19,999 counts in high-resolution mode
Peak captureRecord transients up to 250 us
Min/Max/Avg recordingDisplay signals up to approximately 100 ms
Accuracy specifications are shown as (% of reading + number of digits)
Safety Certifications
ATEXII 2 G Ex ia IIC T4 Gb
II 2 D Ex ia IIIC T130C Db
I M1 Ex ia I Ma
NEC-500Class I, Div 1, Groups A-D, 130C
IEXExEx ia IIC T4 Gb
Ex ia IIIC T130C Db
Ex ia I Ma
GOST R ExOvervoltage protection: Measurement Category III, 1000 V, Pollution Degree 2
Measurement Category IV, 600 V, Pollution Degree 2
IP rating IP67
General Specifications
Power
Three AAA batteries
Battery life: 400 hours
DisplayLCD, with backlight
External protectionRubber holster
WarrantyThree years
Size with holster (H x W x L)6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in)
Weight with holster698.5 g (1.54 lb)











Browse for more products in the same category as this item:

Intrinsically Safe
Intrinsically Safe > Testing and Calibration